Medical water treatment system
Improper medical water treatment will bring great risks to the health and life safety of patients! Therefore, medical water must be treated in a professional way. High-quality medical water treatment is an important guarantee for the life safety and health of doctors and patients.
Aodlon medical water treatment systems can effectively avoid contamination and cross-infection, while also preventing damage to piping systems and expensive equipment.
Water pollution and the current situation of dental clinics
Our country's natural water bodies are seriously polluted. After being treated by water plants, they are transported to thousands of households. Although it has been treated by water plants, due to secondary pollution such as pipelines and water towers, the water contains a large amount of sediment, rust, heavy metals, bacteria, viruses, residual chlorine, colloidal particles, chemical pollutants, etc. when it reaches the water outlet, thus it will be no longer suitable for drinking, does not meet the national drinking water hygiene standards, and cannot be used for medical diagnosis and treatment.
According to the sampling experiments of relevant experts, water samples from the DUWLS output of private dental specialist medical institutions, the dental department of second-level general hospitals, and the dental departments of third-level general hospitals were tested. Among them, 176 water samples collected by private dental specialist medical institutions were qualified. The qualified rate was 31.11%; the dental department of a second-level general hospital collected 41 water samples, with a passing rate of 24.39%; the dental department of a third-level general hospital collected 238 water samples, with a passing rate of 15%; 118 scaler water samples were passed, with the rate 17.8%. It is urgent to disinfect the waterway of the comprehensive dental treatment unit!
During use, many bacteria and viruses can easily adhere to the inner walls of the water pipes of the oral comprehensive treatment unit, forming biofilms and contaminating the waterway environment. Cross-infection is very likely to occur when patients use it.
Dangers of biofilms
If biofilm is not treated in time, it will cause continuous pollution to waterways until the biofilm spreads to the water pipes of the entire equipment. The bacteria and viruses carried by these biofilms can enter the patient's body through mobilephones, dental scalers, three-purpose guns, water in drinking glasses, etc.
During the diagnosis and treatment process, the water mist and aerosol produced by the high-speed turbine handpiece carry a large number of harmful microorganisms shed from the biofilm. Water mist and aerosols continue to spread, seriously polluting the clinic environment and threatening the health of doctors, nurses and patients.
It can cause infections such as COVID-19, influenza, respiratory infections, viral hepatitis and other serious consequences.
Main functions of Aodlon medical water treatment
Main types of bacteria killed
Shigella dysenteriae, pneumoniae, Proteus, Brucella, Clostridium perfringens, Haemophilus influenza, Haemophilus parainfluenzae, Moraxella catarrhalis, Acinetobacter, Yersinia spp., Legionella pneumophila, Bordetella pertussis, Bordetella parapertussis, Shigella spp., Pasteurella spp., Vibrio cholerae, Bacillus parahaemolyticus, Pyropromonas shigella-like, Neisseria meningitidis, Staphylococcus aureus Cocci, Streptococcus, Listeria, Erysipelothrix, Nephrobacter, Bacillus, Clostridium, Mycobacterium, Actinomyces, Nocardia, Corynebacterium, Rhodococcus , Bacillus anthracis, Bacillus erysipelas, Bacillus tetanus, Listeria, Morbacillus perfringens, Bacillus emphysema, Mycobacterium tuberculosis, Legionella, etc.
Main types of viruses killed
HIV, hepatitis A virus, hepatitis B virus, hepatitis C virus, hepatitis D virus, hepatitis C virus, measles virus, polio virus, coxsackie virus, epidemic Japanese encephalitis virus, dengue virus Germ virus, hemorrhagic fever virus, hantavirus, Ebola virus, rabies virus, human immunodeficiency virus, human T-cell virus, herpes simplex virus, varicella-zoster virus, cytomegalovirus, EBV, human papilloma Viruses, rotavirus, coronavirus, rubella virus, Legionnaires’ virus, etc.
Aodlon dental diagnosis and treatment water supply system solution
Aodlon dental diagnosis and treatment water disinfection system National invention patent for active disinfection and sterilization system
● 100% disinfect the 2019-nCoV new coronavirus.
● The total bacterial count of clinical water is 0-10CFU/ml.
● Invention patent for active disinfection and sterilization system.
● Remove radioactive elements such as radium and uranium from water.
● Remove inorganic materials that may damage dental instruments.
● Patented technology liquid separation membrane element: Using Aodlon patented filtration technology, the filtration precision reaches 0.002 micron. It can remove about 70% of positive divalent and polyvalent inorganic salts in water (mainly nitrite and sulfate carcinogenic inorganic substances).
● According to NSF/KTW standards, it can filter out impurities larger than 0.002 microns, including asbestos fibers, E. coli, hepatitis A virus, Legionnaires' disease, Vibrio cholerae, etc. 100% removal of viruses, bacteria, cysts and other harmful microorganisms in water.
● Reduce chemical agents: remove antibiotics, herbicides and pesticides in water >80%, drug residues >90%, adrenal disruptors >90%, remove residual chlorine >95%, remove odors and reduce turbidity.
● Completely solves the cross-infection problem that has been plaguing medical workers during oral diagnosis and treatment, ensuring the safety of doctors and patients.
● Protect expensive water-related equipment and instruments (automatic disinfection cleaners, pulsating vacuum sterilizers, high-pressure steam sterilizers, etc.) from contamination.
● Online detection + dynamic adjustment + remote monitoring + operation records, intelligent operation, ensuring traceability.
Model parameters
Model |
ADL-M5 |
ADL-M6 |
ADL-M7 |
ADL-M8 |
ADL-M9 |
ADL-M10 |
Produced water quality |
Medical cleaning water, drinking water |
Medical cleaning water, softened water, drinking water, steaming and disinfecting water. |
Medical cleaning water, ultra-pure water, softened water, steaming and disinfecting water, drinking water. |
|||
operating mode |
Fully automatic operation, Internet of Things interactive system |
|||||
Water production speed |
Generate custom designs |
|||||
System recovery rate |
>50-80%(Set according to raw water quality) |
|||||
Product water delivery pressure |
0.2~0.45MPa(Freely set as needed) |
|||||
Water production standard |
Water supply complies with "GB5749-2006 Standard" |
Disinfection supply room solutions
Sterile supply room
● Product water quality: complies with the WS310.1213-2009 and 2010 Pharmacopoeia Purified Water Standards and GMP Standards of the Hospital Disinfection Supply Center of the People’s Republic of China
● Inlet water requirements: municipal water supply, 0.15MPa-0.5MPa; Total hardness: <7.5mmol/L (Ca2+); Inlet water temperature: 5-35 Endotoxin and bacteria removal rate ≥99%
● Relative humidity: <-80%, no strong acid, strong alkali and other gases, no strong electromagnetic interference
● Maximum operating pressure: ≤1.50MPa; Operating pressure: 1.05-1.35MPa; RO removal rate: ≥99%
● Site installation requirements: The ground should be equipped with a waterproof layer and floor drain to keep drainage smooth.
● Power supply voltage: AC380V, three-phase five-wire, reliable grounding; power frequency: 50Hz±1Hz
Model parameters
Model parameters:
Model |
Water production(L/H) |
Dimensions(mm) |
Weight (KG) |
Power (KW) |
||
|
|
Length |
Width |
Height |
|
|
ADL-MX-200 |
200 |
650 |
620 |
1700 |
500 |
3 |
ADL-MX-500 |
500 |
830 |
700 |
1700 |
600 |
4 |
ADL-MX-1000 |
1000 |
830 |
620 |
1700 |
500 |
3 |
ADL-MX-1500 |
1500 |
1100 |
700 |
1700 |
600 |
4 |
ADL-MX-2000 |
2000 |
2800 |
900 |
1600 |
750 |
4 |
ADL-MX-2500 |
2500 |
2800 |
900 |
1700 |
800 |
5 |
ADL-MX-3000 |
3000 |
2800 |
900 |
1850 |
900 |
7 |
Laboratory water treatment system
Overview of the functions of Aodlon ultrapure water system
● Adopt reverse osmosis membrane double-stage guarantee process and deep desalination technology, which can meet the needs of high salt water areas.
● Ultrapure water specific resistance online monitoring/water temperature online detection
● Automatic reminder when preprocessing expires
● Microcomputer automatic control, touch button operation
(1) Pretreatment column/RO reverse osmosis membrane/ultrafiltration automatic flushing
(2) When preparing ultrapure water, the LCD screen displays real-time water quality
● System automatic protection function
(1) Automatic or manual shutdown protection when water shortage or water pressure is lower than 0.5bar
(2) Automatic protection of water shortage/low water pressure system (indicator light flashes and alarm sounds)
(3) When the water tank is full, the system automatically shuts down for protection (pure water is displayed as standby)
● With water pressure online monitoring function (optional)
● The water production volume is 15-40 liters/hour, and the water production resistivity reaches 18.2MΩ.cm
● Intelligent computer control system ensures high water quality, online water quality monitoring, real-time monitoring of UP ultrapure water quality, convenient and fast production of RO pure water and UP ultrapure water
● Comprehensive system maintenance and security alarms
● Compatible with two pure water storage methods: pressure bucket and level water tank, and can be equipped with an external large-capacity water storage tank to meet different application needs
Model parameters
Model |
ADL-ML-10 |
ADL-ML-20 |
ADL-ML-40 |
ADL-ML-80 |
ADL-ML-120 |
||
Water production speed |
≥10L/h |
≥20L/h |
≥40L/h |
≥80L/h |
≥120L/h |
||
Incoming water source |
General city tap water, water pressure 1.0-5.0kg/cm², temperature: 5-40℃ |
||||||
Water dispensing speed |
1.5-3L/min |
||||||
Water production index |
Specific resistance: 10-18Ω.cm@25℃,bacteria content<1 /ml |
||||||
Power supply |
220V/50Hz; 50-350W particles( >0.22μm ) <1 /ml |
||||||
Dimension |
340x540x545mm |
490x500x850mm |
1000x650x1130mm |
||||
Consumables situation |
A set of pretreatment, a set of reverse osmosis membrane group, a set of purification column, and a 0.22μm ultrafiltration. The purification column is the main replacement consumable, and the replacement cycle is related to the consumption of ultrapure water. |
Remark: For requirements other than the standard model, it can be customized according to the customer's special requirements such as water volume.